{"product_id":"plattenwaermetauscher-66-kw-anschluesse-2x-3-4-2x-1-2","title":"Plate Heat Exchanger 66 kW – Connections 2× 3\/4″, 2× 1\/2″","description":"\u003cstyle\u003e\n.pb-usp-strip{display:flex;gap:8px;flex-wrap:wrap;margin:0 0 20px}\n.pb-usp-item{flex:1 1 100px;background:#ede8e3;border-radius:8px;padding:10px 8px;text-align:center}\n.pb-usp-item svg{width:22px;height:22px;stroke:#ff2d00;fill:none;stroke-width:1.5;stroke-linecap:round;stroke-linejoin:round;display:block;margin:0 auto 6px}\n.pb-usp-title{display:inline-block;font-family:Montserrat,sans-serif;font-size:12px;font-weight:700;color:#102549;margin-bottom:4px;border:1px solid #ff2d00;border-radius:3px;padding:2px 8px}\n.pb-usp-sub{display:block;font-family:Montserrat,sans-serif;font-size:11px;color:#595959}\n.pb-section-label{display:inline-block;font-family:Montserrat,sans-serif;font-size:13px;font-weight:800;letter-spacing:.07em;text-transform:uppercase;color:#fff;background:#102549;padding:5px 14px;border-radius:4px;margin-bottom:12px}\n.pb-body{font-family:Montserrat,sans-serif;font-size:14.06px;color:#060e2d;line-height:1.75;margin:0 0 14px}\n.pb-divider{border:none;border-top:1px solid #e0e0e0;margin:18px 0}\n.pb-check-list{list-style:none;padding:0;margin:0 0 14px}\n.pb-check-list li{font-family:Montserrat,sans-serif;font-size:14.06px;color:#1a1c1e;padding:4px 0 4px 24px;position:relative;line-height:1.6}\n.pb-check-list li::before{content:\"✓\";position:absolute;left:0;color:#102549;font-weight:700}\n.pb-specs-table{width:100%;border-collapse:collapse;margin:0 0 14px;font-family:Montserrat,sans-serif;font-size:13.5px}\n.pb-specs-table tr{border-bottom:1px solid #ede8e3}\n.pb-specs-table tr:last-child{border-bottom:none}\n.pb-specs-table td{padding:8px 10px;color:#060e2d;vertical-align:top}\n.pb-specs-table td:first-child{color:#595959;width:45%}\n.pb-specs-table td:last-child{font-weight:600}\n.pb-specs-table tr:nth-child(odd){background:#f7f2ed}\n.pb-faq-list{list-style:none;padding:0;margin:0 0 14px}\n.pb-faq-list li{font-family:Montserrat,sans-serif;font-size:13.5px;color:#060e2d;padding:7px 10px;border-left:3px solid #102549;margin-bottom:6px;background:#f7f2ed;border-radius:0 5px 5px 0;line-height:1.6}\n.pb-tags{display:flex;flex-wrap:wrap;gap:6px;margin:0 0 14px}\n.pb-tag{font-family:Montserrat,sans-serif;font-size:12px;font-weight:600;color:#102549;background:#ede8e3;border-radius:4px;padding:4px 10px}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pb-usp-strip\"\u003e\n\n  \u003cdiv class=\"pb-usp-item\"\u003e\n    \u003csvg viewBox=\"0 0 24 24\"\u003e\n      \u003cpath d=\"M13 2L3 14h8l-1 8 10-12h-8z\"\/\u003e\n    \u003c\/svg\u003e\n    \u003cspan class=\"pb-usp-title\"\u003eUp to 130 kW\u003c\/span\u003e\n    \u003cspan class=\"pb-usp-sub\"\u003eEfficient heat transfer in a compact design\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pb-usp-item\"\u003e\n    \u003csvg viewBox=\"0 0 24 24\"\u003e\n      \u003cpath d=\"M4 6h16M4 10h16M4 14h16M4 18h16\"\/\u003e\n    \u003c\/svg\u003e\n    \u003cspan class=\"pb-usp-title\"\u003e60 plates\u003c\/span\u003e\n    \u003cspan class=\"pb-usp-sub\"\u003eLarge heat transfer surface of approx. 0.72 m²\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pb-usp-item\"\u003e\n    \u003csvg viewBox=\"0 0 24 24\"\u003e\n      \u003cpath d=\"M12 2s6 7 6 12a6 6 0 1 1-12 0c0-5 6-12 6-12z\"\/\u003e\n    \u003c\/svg\u003e\n    \u003cspan class=\"pb-usp-title\"\u003eFlow rate up to 4 m³\/h\u003c\/span\u003e\n    \u003cspan class=\"pb-usp-sub\"\u003eEfficient operation in heating and water systems\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pb-usp-item\"\u003e\n    \u003csvg viewBox=\"0 0 24 24\"\u003e\n      \u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\/\u003e\n      \u003cpolyline points=\"9 12 11 14 15 10\"\/\u003e\n    \u003c\/svg\u003e\n    \u003cspan class=\"pb-usp-title\"\u003eStainless steel \u0026 copper\u003c\/span\u003e\n    \u003cspan class=\"pb-usp-sub\"\u003eRobust construction for demanding installations\u003c\/span\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cul class=\"pb-check-list\"\u003e\n  \u003cli\u003e60-plate design for a large heat transfer surface\u003c\/li\u003e\n  \u003cli\u003eMaximum heat output up to 130 kW\u003c\/li\u003e\n  \u003cli\u003eMaximum flow rate up to 4 m³\/h\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions of 191 × 73 × 145 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eProduct description\u003c\/span\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThe B3-12-60 plate heat exchanger is a compact solution designed for efficient heat transfer between two separate circuits. Its construction consists of 60 thin plates, providing a large heat transfer surface while maintaining compact overall dimensions.\n\u003c\/p\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThe heat exchanger is designed for a maximum output of up to 130 kW and a flow rate of up to 4 m³\/h. This makes it suitable for heating installations, domestic hot water systems, heat pumps, solar systems and other applications requiring efficient heat transfer between two separate circuits.\n\u003c\/p\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eEfficient heat transfer\u003c\/span\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThe 60 profiled plates provide an effective heat transfer surface of approximately 0.72 m². The small spacing between the individual plates promotes intensive fluid flow, allowing heat energy to be transferred efficiently between the two circuits.\n\u003c\/p\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThis design combines high thermal performance with compact dimensions. The heat exchanger requires little installation space, making it suitable for systems where available space is limited.\n\u003c\/p\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eApplications\u003c\/span\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThe plate heat exchanger can be used wherever heat needs to be transferred between two separate circuits. It is suitable for heating systems as well as cooling and heat recovery applications.\n\u003c\/p\u003e\n\n\u003cul class=\"pb-check-list\"\u003e\n  \u003cli\u003eCentral heating systems\u003c\/li\u003e\n  \u003cli\u003eDomestic hot water systems\u003c\/li\u003e\n  \u003cli\u003eHeat pumps\u003c\/li\u003e\n  \u003cli\u003eSolar thermal systems\u003c\/li\u003e\n  \u003cli\u003eUnderfloor heating\u003c\/li\u003e\n  \u003cli\u003eHeat recovery systems\u003c\/li\u003e\n  \u003cli\u003eCooling and air-conditioning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eAdvantages\u003c\/span\u003e\n\n\u003cul class=\"pb-check-list\"\u003e\n  \u003cli\u003e60 plates providing a large heat transfer surface\u003c\/li\u003e\n  \u003cli\u003eMaximum heat output up to 130 kW\u003c\/li\u003e\n  \u003cli\u003eFlow rate up to 4 m³\/h\u003c\/li\u003e\n  \u003cli\u003eEffective heat transfer surface of approx. 0.72 m²\u003c\/li\u003e\n  \u003cli\u003eCompact design for space-saving installation\u003c\/li\u003e\n  \u003cli\u003eComponents made of stainless steel and copper\u003c\/li\u003e\n  \u003cli\u003eNo moving parts for low maintenance requirements\u003c\/li\u003e\n  \u003cli\u003eSuitable for a wide range of heating and cooling applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eTechnical specifications\u003c\/span\u003e\n\n\u003ctable class=\"pb-specs-table\"\u003e\n  \u003ctr\u003e\u003ctd\u003eType\u003c\/td\u003e\u003ctd\u003eB3-12-60 plate heat exchanger\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eNumber of plates\u003c\/td\u003e\u003ctd\u003e60\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eMaximum output\u003c\/td\u003e\u003ctd\u003e130 kW\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eMaximum flow rate\u003c\/td\u003e\u003ctd\u003e4 m³\/h (4000 l\/h)\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eVolume\u003c\/td\u003e\u003ctd\u003e1.08 l\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eEffective heat transfer surface\u003c\/td\u003e\u003ctd\u003eapprox. 0.72 m²\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eTemperature range\u003c\/td\u003e\u003ctd\u003e-195 to +225 °C\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eWorking pressure\u003c\/td\u003e\u003ctd\u003e10 bar\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eHeat transfer plate thickness\u003c\/td\u003e\u003ctd\u003e0.26 mm\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eCover plate thickness\u003c\/td\u003e\u003ctd\u003e1.0 mm\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003ePlate spacing\u003c\/td\u003e\u003ctd\u003e2.1 mm\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eF1 and F3 connections\u003c\/td\u003e\u003ctd\u003e½″ – 20.67 mm ISO-G\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eF2 and F4 connections\u003c\/td\u003e\u003ctd\u003e¾″ – 26.16 mm ISO-G\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eMaterial\u003c\/td\u003e\u003ctd\u003eStainless steel, copper\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eDimensions\u003c\/td\u003e\u003ctd\u003e191 × 73 × 145 mm\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr\u003e\u003ctd\u003eFlow circuit\u003c\/td\u003e\u003ctd\u003eF1 → F3 \/ F4 → F2\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eConnections\u003c\/span\u003e\n\n\u003cp class=\"pb-body\"\u003e\nThe heat exchanger is equipped with four connections in two different sizes. Ports F1 and F3 feature ½″ (20.67 mm) ISO-G threads, while ports F2 and F4 feature ¾″ (26.16 mm) ISO-G threads. The intended flow paths are F1 → F3 and F4 → F2.\n\u003c\/p\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eSafety information\u003c\/span\u003e\n\n\u003cul class=\"pb-check-list\"\u003e\n  \u003cli\u003eRead and follow the operating and safety instructions before installation and first use.\u003c\/li\u003e\n  \u003cli\u003eDo not touch the heat exchanger during operation or immediately afterwards, as the surface may become very hot.\u003c\/li\u003e\n  \u003cli\u003eBefore maintenance work, ensure that the system is depressurised and has cooled to ambient temperature.\u003c\/li\u003e\n  \u003cli\u003eRegularly inspect the heat exchanger for signs of leakage or corrosion.\u003c\/li\u003e\n  \u003cli\u003eSuitable frost protection measures must be taken in installations exposed to freezing temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr class=\"pb-divider\"\u003e\n\n\u003cspan class=\"pb-section-label\"\u003eFrequently asked questions\u003c\/span\u003e\n\n\u003cul class=\"pb-faq-list\"\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eHow many plates does the heat exchanger have?\u003c\/strong\u003e\u003cbr\u003e\n    The B3-12-60 model has 60 plates and provides an effective heat transfer surface of approximately 0.72 m².\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eWhat is the maximum output of the heat exchanger?\u003c\/strong\u003e\u003cbr\u003e\n    The specified maximum heat output is 130 kW.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eWhat is the maximum flow rate?\u003c\/strong\u003e\u003cbr\u003e\n    The maximum flow rate is 4 m³\/h, equivalent to 4000 litres per hour.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eWhat connections does the heat exchanger have?\u003c\/strong\u003e\u003cbr\u003e\n    F1 and F3 have ½″ (20.67 mm) ISO-G connections, while F2 and F4 have ¾″ (26.16 mm) ISO-G connections.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eWhat can the plate heat exchanger be used for?\u003c\/strong\u003e\u003cbr\u003e\n    It can be used in heating systems, domestic hot water systems, heat pumps, solar thermal systems, underfloor heating and other applications where heat needs to be transferred between two separate circuits.\n  \u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cdiv class=\"pb-tags\" style=\"margin-top:14px\"\u003e\n  \u003cspan class=\"pb-tag\"\u003e60 Plate Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003e130 kW Plate Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003eB3-12-60\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003eHeat Pump Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003eHot Water Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003eHeating Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003e4 m³\/h Heat Exchanger\u003c\/span\u003e\n  \u003cspan class=\"pb-tag\"\u003eStainless Steel Heat Exchanger\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Shop Pundmann","offers":[{"title":"Default Title","offer_id":55751233601873,"sku":"78835","price":103.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1047\/7548\/3729\/files\/11111111jpg-245784.jpg?v=1794318060","url":"https:\/\/www.pundmann.de\/en\/products\/plattenwaermetauscher-66-kw-anschluesse-2x-3-4-2x-1-2","provider":"Pundmann","version":"1.0","type":"link"}